What it is
CVE-2025-7407 is Netgear D6400 diag.cgi os command injection. A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The...
Vulnerability report
Netgear D6400 diag.cgi os command injection
Netgear / D6400 · 1.0.0.114
Decision summary
Direct answers before the deeper technical record.
What it is
CVE-2025-7407 is Netgear D6400 diag.cgi os command injection. A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The...
Is it exploited?
Yes. Previdian tracks this CVE as a known exploited vulnerability. Confidence is high. Also confirmed by third-party sources.
Who is affected?
Netgear / D6400 1.0.0.114.
What should we do?
Prioritize remediation. Validate affected assets and apply vendor fixes on an accelerated timeline.
Overview
A vulnerability, which was classified as critical, was found in Netgear D6400 1.0.0.114. This affects an unknown part of the file diag.cgi. The manipulation of the argument host_name leads to os command injection. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early and confirmed the existence of the vulnerability. They reacted very quickly, professional and kind.
This vulnerability only affects products that are no longer supported by the maintainer. Es wurde eine kritische Schwachstelle in Netgear D6400 1.0.0.114 gefunden. Es geht dabei um eine nicht klar definierte Funktion der Datei diag.cgi. Mit der Manipulation des Arguments host_name mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann über das Netzwerk passieren. Der Exploit steht zur öffentlichen Verfügung.
Exploitation evidence
Third-party attestation and first-party sensor observation are shown separately so teams can judge the evidence chain.
The Shadowserver
A trusted third party reported exploitation.
Per-source evidence links for KEV attestations are available through the Previdian Pro API.
Learn about Pro API access| Source | Added |
|---|---|
| The Shadowserver First | 2025-07-10 13:32 UTC |
Detection
Make the evidence actionable in scanner, SOC, and edge-control workflows.
Request targets and User-Agents available in Pro. Callback host details available in Enterprise.
No scanner integrations recorded yet.
No Previdian virtual patch is currently available. Future rules ship for ModSecurity, Cloudflare, and AWS WAF.
Learn about virtual patches →No detection artifacts or sensor request patterns are available for this CVE yet.
Check back as sensor telemetry and scanner integrations are updated.
Risk and context
CVSS v4.0
Potential damage if exploited. Separate from whether attackers are using it.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
EPSS
10.4%
Estimated chance of exploitation in the next 30 days. Previdian's warning comes from evidence, not this score.
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:W/RC:C
CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L/E:P/RL:W/RC:C
AV:N/AC:L/Au:S/C:P/I:P/A:P/E:POC/RL:W/RC:C
Timeline
13:32 UTC
Vulnerability disclosed publicly
13:32 UTC
High-confidence, third-party attested exploitation
06:46 UTC
Identifier reserved by the CNA
Pro API
Confidence, exploit status, sensor telemetry, PoCs, scanner integrations, mentions, and tags are available programmatically for VM, SOC, and CTI workflows.
GET /api/v2/pro/kevs/CVE-2025-7407
Free JSON includes basic KEV fields{
"cve_id": "CVE-2025-7407",
"confidence": "High",
"cvss_score": 5.3,
"cvss_estimated": false,
"epss_score": 0.10446,
"exploit_status": {
"exploited_in_the_wild": true,
"active_exploitation_observed": false
},
"sensor_telemetry": { "attempts": 0, "sensors": 0 }
}